There is a product available that at first glance appears to be the cure-all for so many NM cable woes, such as when a NM cable is too short to reach its destination.
#IN WALL SPLICE KIT FOR ROMEX CODE#
NM cable splice kit – Code violation? Is this a repair or rewire? Is there a solution? It depends on the NEC Code cycle that you are working in. An extra receptacle outlet is much cheaper than adding an additional lighting fixture or smoke detector, but none of it is free. The homeowner may be dissatisfied with the news of this surprise outlet since it can spoil the aesthetics of the room, and it can sometimes increase the cost of the project, depending on the type of outlet being proposed. The additional outlet is necessary to serve as the required junction box for tying on a longer piece of NM cable to reach the first electrical outlet in the new room addition.
#IN WALL SPLICE KIT FOR ROMEX INSTALL#
When this is the case we are faced with the arduous task of explaining to the homeowner why we are going to have to install an unplanned receptacle or smoke detector, or even extra lighting fixture in an unconventional -or at least unplanned- location within the new addition. This scenario is even more rewarding when the job pays the contractor the same, regardless of where the contractor finds power for the room.īut what about when this seemingly perfect ready-to-use NM cable whip is too short to reach the proposed location of the first outlet in the new room addition? Sometimes, this kind of existing NM cable whip is left protruding from the exposed edge of an otherwise finished and painted wall, and there is no means for following the cable back to its origin to attach a longer cable. So far, we have described the perfect conditions for wiring a room addition in a snap. This can be an ideal setup that allows the electrical contractor to get the job done quickly while making a fair profit. This provides the electrician with a ready-made NM cable whip conveniently positioned for feeding the first receptacle in the new room addition. If an existing 15- or 20-amp branch circuit is available where the new addition is about to abut the home, the contractor can appoint this existing branch circuit as the new feed for the room addition’s lights and receptacles.

Often an unloaded branch circuit discovered in this area is a dedicated circuit feeding the rear porch receptacle – the same rear porch being torn off the house for the sake of the room addition. In that case, the electrician can find great satisfaction in discovering a 15- or 20-amp branch circuit with little or no load imposed upon it, near the site of the new construction. If the contractor finds the electrical load center is on the opposite end of the home apart from the new addition, they can assume they are in for some work to get at least one new branch circuit to the affected area. Building a room addition over a porch receptacle can provide the needed branch circuit for the addition. Bidding the individual outlets for the new addition is relatively easy, but bidding power to feed them can take some investigation and imagination.
#IN WALL SPLICE KIT FOR ROMEX HOW TO#
If you are an electrical contractor that has ever wired a room addition, you will likely be familiar with this process.īefore ever attempting to provide an estimate, you must first determine how to get power from the home’s existing breaker panel to the new lighting and receptacle outlets in the addition. By: Jerry Durham | 2005–2020 NEC 334.40(B) Devices of Insulating Material